Radiography / Fluoroscopy

Test Device Primus S

Test Device for constancy tests (according to DIN 6868-4, 2007) at digital/conventional fluoroscopic X-ray units with and without radiographic equipment, e.g. Image-intensifier television sets, dynamic flat panels.

Dimensions in mm: 200 x 200 x 18.5


Test Device Primus L

Test Device for constancy tests (according to DIN 6868-4 2007) at digital/conventional fluoroscopic X-ray units with and without radiographic equipment, e.g. Image-intensifier television sets, dynamic flat panels.

Dimensions in mm: 300 x 300 x 18.5


Test Device DIGI-13

For quality tests at all types of CR and DR radiographic systems (homogenity, spatial and contrast resolution, alignment of light field and X-ray field, artifacts) according to DIN 6868-13.


Test Plate ETR1

Test device for quality test at analouge fluroscopic and radiographic systems, according to IEC 61223-2-9 / -11


DSA Test Device RöVi-8

For quality tests in digital subtraction angiography according to IEC 61223-3-3 (DIN 6868-4, 2007).


Contrast-Detail Phantom CDDISC 2.0

For quality control of radiological systems and observer, especially designed for the evaluation of fluoroscopes.


Contrast-Detail Phantom CDRAD

For quality control of radiological systems. This Contrast-Detail-Phantom is an aid for checking the image quality.


Test Plate FFA 4090R

For checking the film-screen contact at radiographic cassettes according to EN ISO 4090.


Test Plate Visi-X

For checking the light and radation field coincidence on X-ray equipment.
Based on self luminencence.
The VISI-X can also be used for checking the centering of the bucky tray.


Beam-Alignment Test Tool (BATT)

For measuring collimator beam alignment of the central beam. (Recommended in combination with DIGI-13, ETR1 and/or Primus)


Grid Alignment Test Tool

Test device for checking the efficiecy of the Bucky grid


Test Set AEC for Radiography

For X-ray units working in the range of 40 - 150 kV according to IEC 61223-2-1.


HVL Aluminum Filter Set

Aluminum attenuator set for HVL measurements at radiographic X-ray units working in range of 40 - 150 kV.
Aluminium purity of 99,5%


Tungsten Edge Test Device TX-5

According to IEC 62220-1
Include tungsten edge for determination of the MTF (modulation transfer function).