myQA Blue Phantom³
Fastest. Most Accurate. Most Flexible water phantom on the market.
Suitable for C-arm, O-shape and robotic linacs
Compatible with Machine/Modality/Application:
TG106,
TG135,
TG148,
TG224,
TG51
Used for Workflow
Commissioning and Annual QA RT,
Commissioning and Annual QA PT
Fastest
- Mechanical auto-leveling in under 30 seconds
- Wi-Fi electrometer
- Single hand pendant
Most Accurate
- Reference class electrometer
- Advanced magnetorestrictive sensors
- Accuracy better than 0.1 mm
- Reduced hysteresis
Flexible
- Leveling on lift table or treatment couch
- No additional accessories for Halcyon®
- Suitable for C-arm, O-shape and robotic linacs
- Measurement setup of your choosing
myQA Blue Phantom³ Water Phantom System
Blue Phantom³ 3D Water Phantom slanted bottom micro-leveling frame
| Scanning volume (L×W×H): | 478mm×478mm×410mm |
| Position accuracy/reproducibility: | +/- 0.1mm/0.1mm |
| Position resolution: | 0.1mm |
| Scanning speed: | 25mm/sec |
| Volume (approx.): | 200 liters |
| Accuracy of auto-leveling: | +/- 0.025 degrees |
Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.
CCU-X electrometer
| Input: | two independent reference class electrometers |
| Bias voltage: | ±50V – ±500V, ±2% |
| Leakage: | <100 fA, typically < 40 fA |
| Ranges: | 400 fA–600 pA, 6pA–60nA, 2.4nA–24µA |
| Resolution: | ■ 0.12 fA at 0.6 nA full scale ■ 12 fA at 60 nA full scale ■ 4.8 pA at 24 µA full scale |
| Time constant | 22 ms |
| Ethernet cable and Wi-Fi |
Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.
Blue Phantom³ Lift Table telescopic legs extendable up to 180cm
| Maximum load capacity: | 250kg |
| Vertical range/speed: | 660–1180mm / 13mm/sec |
| Table size: | 680mm×680mm, thickness 19mm |
Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.
Blue Phantom³ Water Reservoir with accessory storage
| Pump capacity: | Max. 40l/min. |
| Pump: | DC motor 24V, 750W, bi-directional |
| Tank volume: | 208 liters |
Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.
Built Around the Real Challenges of Water Tank QA
For more than 50 years, IBA has partnered with medical physicists worldwide.
Through field insights, hands-on collaboration, and recent customer feedback, we identified the specific challenges that impact daily water tank measurements — and built solutions around them.
Our focus: reduce setup variability, improve measurement accuracy, and streamline workflows in real clinical environments.
| Data Quality & Processing | High-resolution acquisition and magneto restrictive technology minimize noise and ensure accurate PDDs and profiles — reducing the need for repeat scans and manual corrections. |
| Detector Positioning | Simplified detector mounting and freedom of choice with chamber holder fully independent from vendors for better focus on careful alignment checks. |
| Detector Selection | Guided detector recommendations eliminate guesswork and reduce setup errors — especially during commissioning or when switching detectors. |
| Repeatability & Reproducibility | User-independent autoleveling combined with controlled motion enables reproducible results over time, reducing inter-user variability and ensuring long-term QA consistency. |
| Setup | Automatic leveling ensures accurate alignment — regardless of who performs the setup. Ready to measure in under 30 seconds, with no additional equipment required. |
| Time | Optimized scan speed and streamlined workflows reduce measurement time without increasing noise or compromising accuracy. Fewer manual adjustments. Fewer repeated scans. More predictable commissioning timelines. |
What our customers say
Find more resources here
Brochures
Articles
Teaser Videos
myQA Blue Phantom³ - main features
Fastest. Most accurate. Most flexible.
Trusted by vendors and physicists.