myQA MatriXX AiR

Wireless, High-Precision
Ion Chamber Detector Array

Bringing next level PSQA confidence to advanced Particle Therapy applications.
 
Reliable. Fast. FLASH Ready.

Compatible with Machine/Modality/Application:

Synchro-Cyclotron,

Cyclotrons,

Proton Therapy,

TG224,

Ultra-high Dose Rate (UHDR),

Carbon Compatible

Used for Workflow

Delivery and Plan Verification PT

Get in touch Get brochure
Top view

Move from planning confidence to treatment confidence

MatriXX AiR represents the next step toward fully realizing treatment confidence in proton and carbon-ion therapy. 

Engineered as a high-resolution, air-vented ionization chamber array, it is designed to deliver precise 2D dose-distribution measurements for increasingly complex particle-therapy plans. Its capability to characterize and verify critical treatment parameters positions it as a strategic tool for centers preparing for the next wave of clinical and regulatory expectations.

In particle therapy, patient-specific quality assurance is essential to confirm that delivered distributions align with the planned treatment. IBA’s detector arrays have already proven their value in proton-therapy PSQA for their spatial resolution and workflow efficiency, and MatriXX AiR is built to elevate these strengths. 

With hardware and software components that support verification of  ultra-high-dose-rate (UHDR) ion-beam delivery, it is your ally in meeting the rigor and sophistication required for emerging FLASH radiotherapy programs.

Now verify complex particle plans in minutes, freeing clinical bandwidth while meeting the precision, consistency and standards needed in next generation cancer care.

Features

Wireless, Clinical Efficiency Built In

Wireless, Clinical Efficiency Built In

MatriXX AiR is the first commercially available wireless ion chamber array, designed for seamless PSQA in proton and heavy ion therapy. With WiFi and battery operation, it brings flexibility to your clinical environment. 

Lightweight (~7.3 kg) and cable-free setup cuts couch time; automated k (T,P) correction plus robust chamber stability translate to day-to-day reproducibility you can trust.

High-Density Detector Matrix

High-Density Detector Matrix

Equipped with 1521 air-vented ionization chambers across a 25 × 25 cm² field, delivering a 6.5 mm center-to-center resolution ideal for capturing fine dose gradients.

Ready for Cyclotron FLASH (UHDR) applications

Ready for Cyclotron FLASH (UHDR) applications

Engineered with a 1 mm electrode gap to support ultra-high dose rate (UHDR) and FLASH protocols with minimal recombination loss.
MatriXX Air accurately measures UHDR dose delivery produced by a quasi-continuous particle beam, providing the reliable verification needed for clinics to confidently implement FLASH therapy.

 

Advanced Compatibilities

Advanced Compatibilities

  • Purpose-built for pencil beam scanning and SOBP deliveries with fast, reliable performance tailored to particle therapy QA workflows.
  • Fully functional with quasi-continuous and pulsed particle beams.
  • Compatible with Arc Particle Therapy.
  • Integrates smoothly with the Gantry Angle Sensor for beam angle tracking. 

Fast Readout Cycle

Fast Readout Cycle

Complete dose distribution readout in just 20 milliseconds, enables rapid turnaround for patient plan verification, a level of performance that is unmatched in the industry. Ideal for busy clinical schedules and high-throughput centers

Wireless, Clinical Efficiency Built In

MatriXX AiR is the first commercially available wireless ion chamber array, designed for seamless PSQA in proton and heavy ion therapy. With WiFi and battery operation, it brings flexibility to your clinical environment. 

Lightweight (~7.3 kg) and cable-free setup cuts couch time; automated k (T,P) correction plus robust chamber stability translate to day-to-day reproducibility you can trust.

High-Density Detector Matrix

Equipped with 1521 air-vented ionization chambers across a 25 × 25 cm² field, delivering a 6.5 mm center-to-center resolution ideal for capturing fine dose gradients.

Ready for Cyclotron FLASH (UHDR) applications

Engineered with a 1 mm electrode gap to support ultra-high dose rate (UHDR) and FLASH protocols with minimal recombination loss.
MatriXX Air accurately measures UHDR dose delivery produced by a quasi-continuous particle beam, providing the reliable verification needed for clinics to confidently implement FLASH therapy.

 

Advanced Compatibilities

  • Purpose-built for pencil beam scanning and SOBP deliveries with fast, reliable performance tailored to particle therapy QA workflows.
  • Fully functional with quasi-continuous and pulsed particle beams.
  • Compatible with Arc Particle Therapy.
  • Integrates smoothly with the Gantry Angle Sensor for beam angle tracking. 

Fast Readout Cycle

Complete dose distribution readout in just 20 milliseconds, enables rapid turnaround for patient plan verification, a level of performance that is unmatched in the industry. Ideal for busy clinical schedules and high-throughput centers

ePosters

Evaluation of the 2D array MatriXX AiR prototype for patient-specific quality assurance in carbon ion therapy.

Download Poster

Validation of tools for the full dosimetry chain in PBS proton quasi-continuous ultra-high dose rate beams

Download Poster

Get in touch now! 

Our experts will find the perfect solution for you.

Clinical Workflow Integration with myQA Patients Software

  • Reliable and efficient four-step Patient QA workflow.
  • Fast and reproducible measurements and analysis.

    Read More

 

Values

Fastest

Fastest

  • Seamless and intuitive, from set-up to measurements and analysis
  • Optimized workflow with myQA® for plan verification 

Most Accurate

Most Accurate

  • Shortest 20 ms sampling time: real-time measurements for rapidly changing fields and doses  
  • Proven technology for Proton Therapy Beams and also for Synchro-Cyclotron systems 

Most Reliable

Most Reliable

  • Ion chambers offer a long term stability and measurement without blind spots
  • Your data is safely stored in one central database within myQA
  • Data integrity with an advanced user management system 

Fastest

  • Seamless and intuitive, from set-up to measurements and analysis
  • Optimized workflow with myQA® for plan verification 

Most Accurate

  • Shortest 20 ms sampling time: real-time measurements for rapidly changing fields and doses  
  • Proven technology for Proton Therapy Beams and also for Synchro-Cyclotron systems 

Most Reliable

  • Ion chambers offer a long term stability and measurement without blind spots
  • Your data is safely stored in one central database within myQA
  • Data integrity with an advanced user management system 

Technical Specifications

Specifications

Specifications

Field size/active measurement area25x25cm
Number of detectors 1521
Resolution (center-center distance)6.5mm
Detector/sensor type Vented parallel plateion chambers
Director diameter x depth3.2x1.0mm
Single Chamber volume 8mm³
Device dimensions57.6x32x4cm
Device weight7.3kg (including battery)
Supported beamsParticles (e.g protons or carbon ions)
PowerRechargeable battery or/Plugged in 
Data transferWireless or Ethernet

Specifications

Field size/active measurement area25x25cm
Number of detectors 1521
Resolution (center-center distance)6.5mm
Detector/sensor type Vented parallel plateion chambers
Director diameter x depth3.2x1.0mm
Single Chamber volume 8mm³
Device dimensions57.6x32x4cm
Device weight7.3kg (including battery)
Supported beamsParticles (e.g protons or carbon ions)
PowerRechargeable battery or/Plugged in 
Data transferWireless or Ethernet

Find more resources here

Brochures

Scientific References

MatriXX AiR
Brochures (12 MB)
Download now
Validation of tools for the full dosimetry chain in PBS proton quasi-continous ultra-high dose rate beams
Scientific References (710 KB)
Download now
Evaluation of the 2D array MatriXX AiR prototype for patient-specific quality assurance in carbon ion therapy
Scientific References (1 MB)
Download now

Contact us for more information