IBA Dosimetry myQA SRS - Headerimage

myQA® SRS*

The digital SRS/SBRT Patient QA Solution

The new myQA SRS solution uniquely combines the best of both worlds:

  • unrivaled accuracy and resolution of film QA,
  • with the proven efficiency of digital detector array workflow.

 

Treat more SRS/SBRT patients safely and with the confidence it’s done right. 

 

 

Contact us for your individual solution!
IBA Dosimetry myQA SRS - Benefits
Begin Benefit
myQA SRS Image for Hotspots

Film Class detector array optimal for SRS/SBRT

  • Unique solid-state sensor array.
  • 105,000 pixels total.
  • 0.4 mm resolution.
IBA Dosimetry myQA SRS - Res

Light field check

  • Field size markers 5x5 and 10x10 cm².
  • Easy verification of the light field’s conformity with the radiation field.

Laser setup marker

  • Precise and fast setup through laser alignment.
IBA Dosimetry myQA SRS - Laser Alignment

Designed for non-coplanar fields

  • Compact design enables QA of flexible SRS beam rotation angles.
IBA Dosimetry myQA SRS - man

Gantry Sensor+

  • QA accuracy for rotational cases.
  • Accurate measurements of your Linac rotation angles corresponding to your detector measurement.
  • Easy setup without cables with wireless data exchange.
IBA Dosimetry myQA SRS - Gantry Sensor+

Largest high-resolution stereotactic detector field

  • 120x140 mm² active array.
  • Efficient QA of multiple stereotactic targets in one measurement setup.
IBA Dosimetry myQA SRS - Field

The myQA SRS Phantom

  • For verification of single beams and for composite SRS plans using the myQA SRS detector.
IBA Dosimetry myQA SRS - Product Phantom

myQA Patients Software - Workflow efficiency for SRS measurements and analysis

  • Smart software reduces typical SRS validation times:
  • Automatic alignment of the dose distributions.
  • Field by field measurements for precise SRS technique verification.
  • Automated beam-triggered measurement mode: save multiple mouse clicks and get QA results within seconds.
IBA Dosimetry myQA SRS - myQA Patients

Stereotactic Patient QA -

Prioritizing accuracy, workflow efficiency and throughput in the SRS/SBRT

Read the article from Physics World based on an interview conducted with IBA Dosimetry product manager and nuclear engineer about the advantages and physics testing of the new myQA SRS solution.  

Download PDF

IBA Dosimetry myQA SRS - Mockup Interview

When Accuracy matters, Resolution matters!

myQA SRS provides the clinical resolution needed for the most advanced QA:

  • Measurement-based Patient QA is strongly encouraged e.g. by AAPM-RSS Medical Physics Practice Guideline 9.a. for SRS/SBRT.
  • However, publications have shown that “detector resolution is of main importance to avoid getting false positive [QA results].” 
    A. Bruschi et al.: Detector resolution affects the clinical significance of SBRT QA. Find link to Publication here.
  • Other commercially available detector arrays for SRS/SBRT do not provide sufficient measurement resolution.
  • myQA SRS is the new and unique solution providing film-class resolution clinically needed to avoid false QA results.

IBA Dosimetry myQA SRS - Old vs New

IBA Dosimetry myQA SRS - Timeplan

Save hours of QA time vs. typical film dosimetry.  

Contact your IBA Dosimetry expert to find out more


The complete SRS / SBRT QA Solution 

The myQA SRS Phantom

  • For verification of single beams and for composite SRS plans using the myQA SRS detector.
  • Cylindrical shape with cap for non-coplanar arc delivery.
  • Easy setup on the couch through lightweight design and laser alignment markers.
  • Including dedicated inserts for small field dosimetry chambers.
  • Optional film insert for benchmarking and for your seamless transition from film-based QA to myQA SRS QA.
IBA Dosimetry myQA SRS - Product Phantom

IBA Dosimetry myQA SRS - FAQ

Questions about stereotactic Patient QA?

If you are curious about details and facts, we are happy to provide them. 
You can find them here:  

FAQs

End Benefit

* myQA SRS is currently not available for sale in the USA. The product may not be available in your area. For availability, please contact your local IBA Dosimetry Sales organization.

IBA Dosimetry myQA SRS - gallery Image product
IBA Dosimetry myQA SRS - gallery Image product phantom
IBA Dosimetry myQA SRS - gallery Image Scene
IBA Dosimetry myQA SRS - gallery Image Scene
IBA Dosimetry myQA SRS - gallery Image gamma verification
IBA Dosimetry myQA SRS - gallery Image resolution

Related Products

IBA Dosimetry Product SciMoCa

Monte Carlo Accuracy

Secondary Dose Check & 3D Plan QA

Discover
IBA Dosimetry MatriXX Resolution

MatriXX Resolution*

Highest resolution for IMRT & VMAT
Patient QA measurements
and Machine QA

Discover
IBA Dosimetry myQA Patients Logo

myQA Patients

Patient QA solution for gamma verification of dose distributions

Discover
iba Dosimetry standard detector vs film class popup

Watch Online Presentation with updates and physics test information of myQA SRS

Watch Online Presenation