myQA StarTrack³

One setup. One detector. Complete beam insight.

Compatible with Machine/Modality/Application:

C-arm linacs,

Bore-type linacs,

TG142

Used for Workflow

Commissioning and Annual QA RT,

Monthly QA RT

Get in touch Get brochure

Precision

Water tank confidence, powered by a high-definition array

Coverage

Real-time beam steering with comprehensive field coverage

Efficiency

Optimized QA workflow

Less complexity. More confidence. Every check.

At IBA Dosimetry, we work closely with medical physicists to support what matters most: faster setup, fewer uncertainties, and reproducible results you can rely on over time. By removing friction from routine and annual QA, our approach helps you spend less time managing equipment and more time delivering safe, precise treatments — with confidence at every check.

  • Water tank confidence, powered by a high-definition array: High‑level accuracy (±0.5%) with no warm‑up, pumps, or complex setup — ideal for frequent checks.
  • Real-time beam steering with comprehensive field coverage: Instant, quantitative feedback across the entire field (≥30×30 cm including tails) for fast tuning, verification, and confident trending — in the time it takes to deliver the beam.
  • Optimized QA workflow: Capture output, beam quality, flatness, symmetry, field size, and penumbra in a single quick measurement — monthly QA in minutes (including setup).

Workflow simplicity

myQA StarTrack³ is optimized for your workflow efficiency. Maximize productivity with fast, reliable results delivered in under five minutes, from setup to measurement and verification.

myQA StarTrack³ at a glance

1

Cutouts

for convenient and  secure device handling

2

Light field check

QA test for quantitative results available in software

3

Wireless data exchange

for convenient cable-free workflow, and optional Ethernet LAN connection possible

4

Rechargeable battery

ensures a fast setup between linacs

5

Laser markers

for ease of device alignment and setup

6

Machine QA measurements up to 34x34 cm² field size

Integrated energy check chambers for photon and electron beams

7

High resolution enabled for precise measurements

2.5 mm resolution center-to-center on field edges at 10x10, 20x20 and 30x30

  • 9 central chambers for accurate dose reading
  • 509 ionization chambers
  • 5 mm center-to-center chamber distance on primary axes and 7.1 mm on diagonals
8

myQA StarTrack³ Software

provides a centralized, web‑based repository for trendable QA data, accessible anytime, anywhere. Built‑in Machine QA tests — such as automatic energy validation, light/radiation field coincidence, output constancy, and profile constancy — are available by default. Flexible analysis protocols allow beam profiles to be reviewed in relative, counts, or absolute modes.

9

Energy verification

and consistency ensured with delivered electron and photon energy verification plates

  • Photon energy verification plate provides TPR20,10 value
  • Electron energy verification plate provides R50 value
  • In less than a minute

1 Cutouts

for convenient and  secure device handling

2 Light field check

QA test for quantitative results available in software

3 Wireless data exchange

for convenient cable-free workflow, and optional Ethernet LAN connection possible

4 Rechargeable battery

ensures a fast setup between linacs

5 Laser markers

for ease of device alignment and setup

6 Machine QA measurements up to 34x34 cm² field size

Integrated energy check chambers for photon and electron beams

7 High resolution enabled for precise measurements

2.5 mm resolution center-to-center on field edges at 10x10, 20x20 and 30x30

  • 9 central chambers for accurate dose reading
  • 509 ionization chambers
  • 5 mm center-to-center chamber distance on primary axes and 7.1 mm on diagonals

8 myQA StarTrack³ Software

provides a centralized, web‑based repository for trendable QA data, accessible anytime, anywhere. Built‑in Machine QA tests — such as automatic energy validation, light/radiation field coincidence, output constancy, and profile constancy — are available by default. Flexible analysis protocols allow beam profiles to be reviewed in relative, counts, or absolute modes.

9 Energy verification

and consistency ensured with delivered electron and photon energy verification plates

  • Photon energy verification plate provides TPR20,10 value
  • Electron energy verification plate provides R50 value
  • In less than a minute

myQA StarTrack³ system

myQA StarTrack³ detector array

myQA StarTrack³ detector array

Field size / active measurement area (cm)34 x 34
Number of ion chambers509
Resolution (center-center distance) (mm)5.0 (main axes)
2.5 (field edges)
7.1 (diagonals)
Detector / sensor type Vented parallel plate
ion chamber
Detector size / chamber size (mm)3.2 × 2.0
Total chamber volume (mm³)16.08
Outer dimensions [LxWxH] [mm]666 x 430 x 40
Array weight (kg)9.8 (including battery)
Supported energiesPhotons (FF/FFF) [MV]: 6/6 FFF, 10/10 FFF, 15, 18
Electrons (MeV): 6, 9, 12, 15, 18
PowerRechargeable battery incl. battery charger 
9V power supply
Data transferWireless or Ethernet

 

Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.

myQA StarTrack³ web-based application

myQA StarTrack³ web-based application

Fully independent access via web-based application
 

Server installation (recommended)Deployment on physical or virtual servers
Supported server operating system: Windows server 20221
HW resources: CPU: 4 cores/2 GHz recommended
Recommended operating system of the client machine is Windows 111
Personal computer installation
 
Supported operating system: Windows 111
CPU: 2 cores/2 GHz recommended
Minimum hardware requirements 
(for server installation and personal computer installation)
Disk space: 0.5 MB/measurement (200 GB recommended in typical cases)
RAM: 16 GB recommended
Installation of MSSQL server (2022) is required
Supported transmission speed for network interface card: 10/100/1000 Base T
The application is accessed with a web browserSupported browsers: Microsoft Edge1 (version 140 or newer), Google ChromeTM (version 140 or newer) and Mozilla Firefox2 (version 143 or newer)
Recommended display resolution: 1920x1080, 100% scaling



1 Windows 11, Windows Server 2022 and Microsoft Edge are trademarks of the Microsoft group of companies. 
2 Firefox is a trademark of the Mozilla Foundation in the U.S. and other countries.

myQA StarTrack³ detector array

Field size / active measurement area (cm)34 x 34
Number of ion chambers509
Resolution (center-center distance) (mm)5.0 (main axes)
2.5 (field edges)
7.1 (diagonals)
Detector / sensor type Vented parallel plate
ion chamber
Detector size / chamber size (mm)3.2 × 2.0
Total chamber volume (mm³)16.08
Outer dimensions [LxWxH] [mm]666 x 430 x 40
Array weight (kg)9.8 (including battery)
Supported energiesPhotons (FF/FFF) [MV]: 6/6 FFF, 10/10 FFF, 15, 18
Electrons (MeV): 6, 9, 12, 15, 18
PowerRechargeable battery incl. battery charger 
9V power supply
Data transferWireless or Ethernet

 

Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.

myQA StarTrack³ web-based application

Fully independent access via web-based application
 

Server installation (recommended)Deployment on physical or virtual servers
Supported server operating system: Windows server 20221
HW resources: CPU: 4 cores/2 GHz recommended
Recommended operating system of the client machine is Windows 111
Personal computer installation
 
Supported operating system: Windows 111
CPU: 2 cores/2 GHz recommended
Minimum hardware requirements 
(for server installation and personal computer installation)
Disk space: 0.5 MB/measurement (200 GB recommended in typical cases)
RAM: 16 GB recommended
Installation of MSSQL server (2022) is required
Supported transmission speed for network interface card: 10/100/1000 Base T
The application is accessed with a web browserSupported browsers: Microsoft Edge1 (version 140 or newer), Google ChromeTM (version 140 or newer) and Mozilla Firefox2 (version 143 or newer)
Recommended display resolution: 1920x1080, 100% scaling



1 Windows 11, Windows Server 2022 and Microsoft Edge are trademarks of the Microsoft group of companies. 
2 Firefox is a trademark of the Mozilla Foundation in the U.S. and other countries.

Get in touch now!

Our experts will find the perfect solution for you.

Find more resources

Brochures

myQA StarTrack³
Brochures (2 MB)
Download now

Gallery

  • Alignment markers

  • Large field size

  • Compatible with multiple linac configurations

myQA StarTrack³

One setup. One detector. Complete beam insight.

Load More

Contact us for more information

Related Products