myQA StarTrack³
One setup. One detector. Complete beam insight.
Used for Workflow
Commissioning and Annual QA RT,
Monthly QA RT
Precision
Water tank confidence, powered by a high-definition array
Coverage
Real-time beam steering with comprehensive field coverage
Efficiency
Optimized QA workflow
Less complexity. More confidence. Every check.
At IBA Dosimetry, we work closely with medical physicists to support what matters most: faster setup, fewer uncertainties, and reproducible results you can rely on over time. By removing friction from routine and annual QA, our approach helps you spend less time managing equipment and more time delivering safe, precise treatments — with confidence at every check.
- Water tank confidence, powered by a high-definition array: High‑level accuracy (±0.5%) with no warm‑up, pumps, or complex setup — ideal for frequent checks.
- Real-time beam steering with comprehensive field coverage: Instant, quantitative feedback across the entire field (≥30×30 cm including tails) for fast tuning, verification, and confident trending — in the time it takes to deliver the beam.
- Optimized QA workflow: Capture output, beam quality, flatness, symmetry, field size, and penumbra in a single quick measurement — monthly QA in minutes (including setup).
Workflow simplicity
myQA StarTrack³ is optimized for your workflow efficiency. Maximize productivity with fast, reliable results delivered in under five minutes, from setup to measurement and verification.
myQA StarTrack³ at a glance
Cutouts
for convenient and secure device handling
Light field check
QA test for quantitative results available in software
Wireless data exchange
for convenient cable-free workflow, and optional Ethernet LAN connection possible
Rechargeable battery
ensures a fast setup between linacs
Laser markers
for ease of device alignment and setup
Machine QA measurements up to 34x34 cm² field size
Integrated energy check chambers for photon and electron beams
High resolution enabled for precise measurements
2.5 mm resolution center-to-center on field edges at 10x10, 20x20 and 30x30
- 9 central chambers for accurate dose reading
- 509 ionization chambers
- 5 mm center-to-center chamber distance on primary axes and 7.1 mm on diagonals
myQA StarTrack³ Software
provides a centralized, web‑based repository for trendable QA data, accessible anytime, anywhere. Built‑in Machine QA tests — such as automatic energy validation, light/radiation field coincidence, output constancy, and profile constancy — are available by default. Flexible analysis protocols allow beam profiles to be reviewed in relative, counts, or absolute modes.
Energy verification
and consistency ensured with delivered electron and photon energy verification plates
- Photon energy verification plate provides TPR20,10 value
- Electron energy verification plate provides R50 value
- In less than a minute
1 Cutouts
for convenient and secure device handling
2 Light field check
QA test for quantitative results available in software
3 Wireless data exchange
for convenient cable-free workflow, and optional Ethernet LAN connection possible
4 Rechargeable battery
ensures a fast setup between linacs
5 Laser markers
for ease of device alignment and setup
6 Machine QA measurements up to 34x34 cm² field size
Integrated energy check chambers for photon and electron beams
7 High resolution enabled for precise measurements
2.5 mm resolution center-to-center on field edges at 10x10, 20x20 and 30x30
- 9 central chambers for accurate dose reading
- 509 ionization chambers
- 5 mm center-to-center chamber distance on primary axes and 7.1 mm on diagonals
8 myQA StarTrack³ Software
provides a centralized, web‑based repository for trendable QA data, accessible anytime, anywhere. Built‑in Machine QA tests — such as automatic energy validation, light/radiation field coincidence, output constancy, and profile constancy — are available by default. Flexible analysis protocols allow beam profiles to be reviewed in relative, counts, or absolute modes.
9 Energy verification
and consistency ensured with delivered electron and photon energy verification plates
- Photon energy verification plate provides TPR20,10 value
- Electron energy verification plate provides R50 value
- In less than a minute
myQA StarTrack³ system
myQA StarTrack³ detector array
| Field size / active measurement area (cm) | 34 x 34 |
| Number of ion chambers | 509 |
| Resolution (center-center distance) (mm) | 5.0 (main axes) |
| 2.5 (field edges) | |
| 7.1 (diagonals) | |
| Detector / sensor type | Vented parallel plate |
| ion chamber | |
| Detector size / chamber size (mm) | 3.2 × 2.0 |
| Total chamber volume (mm³) | 16.08 |
| Outer dimensions [LxWxH] [mm] | 666 x 430 x 40 |
| Array weight (kg) | 9.8 (including battery) |
| Supported energies | Photons (FF/FFF) [MV]: 6/6 FFF, 10/10 FFF, 15, 18 Electrons (MeV): 6, 9, 12, 15, 18 |
| Power | Rechargeable battery incl. battery charger |
| 9V power supply | |
| Data transfer | Wireless or Ethernet |
Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery.
myQA StarTrack³ web-based application
Fully independent access via web-based application
| Server installation (recommended) | Deployment on physical or virtual servers |
| Supported server operating system: Windows server 20221 | |
| HW resources: CPU: 4 cores/2 GHz recommended | |
| Recommended operating system of the client machine is Windows 111 | |
| Personal computer installation | Supported operating system: Windows 111 |
| CPU: 2 cores/2 GHz recommended | |
| Minimum hardware requirements (for server installation and personal computer installation) | Disk space: 0.5 MB/measurement (200 GB recommended in typical cases) |
| RAM: 16 GB recommended | |
| Installation of MSSQL server (2022) is required | |
| Supported transmission speed for network interface card: 10/100/1000 Base T | |
| The application is accessed with a web browser | Supported browsers: Microsoft Edge1 (version 140 or newer), Google ChromeTM (version 140 or newer) and Mozilla Firefox2 (version 143 or newer) |
| Recommended display resolution: 1920x1080, 100% scaling |
1 Windows 11, Windows Server 2022 and Microsoft Edge are trademarks of the Microsoft group of companies.
2 Firefox is a trademark of the Mozilla Foundation in the U.S. and other countries.
Gallery
myQA StarTrack³
One setup. One detector. Complete beam insight.