PhantomX Head Phantom 

This phantom simulates a head with stroke and bleeding patterns. It covers the vertex to the foramen magnum.

Compatible with Machine/Modality/Application:

CT Simulation,

CBCT,

Head

Used for Workflow

Head

Get in touch Get brochure

Head Phantom Stroke / Bleed

This phantom simulates a head with stroke and bleeding patterns. It covers the vertex to the foramen magnum.

Stroke patterns include signs of early infarction (hyperdense middle cerebral artery, disappearing basal ganglia), acute and subacute watershed infarcts, and lacunar infarctions of varying ages.

Bleeding patterns include subarachnoid hemorrhage, subdural hemorrhage of varying ages, intraventricular hemorrhage, and intracerebral hemorrhage.

The phantom can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnosis. It is also suited for training purposes.The phantom provides a detailed and realistic simulation of common brain pathologies, soft and bone tissues. Air voids are filled with a cellulose-polymer composite of approx. -160 HU.

Features

Specifications

Specifications

SizeApprox. 190 x 210 x 147 mm 
WeightApprox. 2640 g
Base MaterialCellulose-polymer composite
Optimal tube voltage120 kVp - adaptable upon request

 

Diagnostic Features

Diagnostic Features

Stroke

  • Hyperdense middle cerebral artery (MCA) and disappearing basal ganglia on the left side
  • Watershed infarcts in middle/posterior (MCA/PCA) and anterior/middle cerebral artery (ACA/MCA) territories
  • 8 lacunar infarcts of varying ages

Hemorrhage

  • Subarachnoid hemorrhage (2 territories)
  • Subdural hemorrhage of varying ages (3 territories)
  • Intraventricular hemorrhage (left lateral ventricle)
  • Intracerebral hemorrhage (2 thalamic, 6 subcortical)

Packaging & Dimensions

Packaging & Dimensions

The product ships in a protective hard case featuring interior foam padding.

  • Dimensions (case): 415 × 280 × 190 mm
  • Dimensions (packaged)*: 465 × 355 × 210 mm
  • Total weight (ready to ship): 9.0 kg

*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.

Specifications

SizeApprox. 190 x 210 x 147 mm 
WeightApprox. 2640 g
Base MaterialCellulose-polymer composite
Optimal tube voltage120 kVp - adaptable upon request

 

Diagnostic Features

Stroke

  • Hyperdense middle cerebral artery (MCA) and disappearing basal ganglia on the left side
  • Watershed infarcts in middle/posterior (MCA/PCA) and anterior/middle cerebral artery (ACA/MCA) territories
  • 8 lacunar infarcts of varying ages

Hemorrhage

  • Subarachnoid hemorrhage (2 territories)
  • Subdural hemorrhage of varying ages (3 territories)
  • Intraventricular hemorrhage (left lateral ventricle)
  • Intracerebral hemorrhage (2 thalamic, 6 subcortical)

Packaging & Dimensions

The product ships in a protective hard case featuring interior foam padding.

  • Dimensions (case): 415 × 280 × 190 mm
  • Dimensions (packaged)*: 465 × 355 × 210 mm
  • Total weight (ready to ship): 9.0 kg

*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.

Get in touch now!

Our experts will find the perfect solution for you.

Find more resources here

Brochures

Articles

PhantomX - Head Neck Phantom Brochure
Brochures (3 MB)
Download now
Head Phantom - Data Sheet
Brochures (1 MB)
Download now
When AI Meets Reality: Why Radiologists Need PhantomX
From Geometric Phantoms to Clinically Predictive Testing_The Evolving Role of Phantom-Based QA in MI _ EFOMP2026 Summer edition
Articles (485 KB)
Download now
Inconsistency of AI in intracranial aneurysm detection with varying dose and image reconstruction_June 2025
Articles (393 KB)
Download now

Clinically Realistic Phantoms for End-to-End Imaging and AI QA

PhantomX supplies a new generation of highly realistic phantoms for clinical imaging and AI in medical imaging. Advanced technologies, innovation and and science are used to create optimal solutions for clinical diagnostic workflows. Accelerated development, improved diagnostic outcomes and reliable AI deployment can improve patient care, efficiency and accessibility in diagnostic imaging. 

Dr. Paul Jahnke

Radiologist and Researcher, Charité Berlin, Founder PhantomX

16 (open access preview)
Full presentation, for members (16)
Discover more
Load More

Contact us for more information