PhantomX Head/Neck Phantom
Simulate true anatomical detail and vascular structures to elevate your imaging performance and AI-driven diagnostics.
Compatible with Machine/Modality/Application:
Heaad,
Neck,
CT Simulation,
CBCT
Head / Neck Phantom CTA
This phantom simulates a contrast-enhanced head in the arterial phase (CT angiography), including the neck and upper thorax up to the aortic arch and the fifth thoracic vertebra. The vertex is included to approximately 0.5 cm below the skin level. The thoracic section excludes shoulder and back parts that are typically not part of CTA examinations.
The internal carotid arteries feature bilateral calcifications, with moderate stenosis on the right side, while no other significant vascular pathologies are present. The phantom provides a detailed and realistic representation of vascular structures, soft tissue, and bone, including fine anatomical details such as lymph nodes. Air voids are filled with a cellulose-polymer composite with an attenuation of approximately −160 HU.
It can be used in CT (including CBCT) to evaluate and optimize CTA imaging performance and post-processing applications such as vessel segmentation, including AI-enabled solutions, and is also well suited for training purposes.
Features
Specifications
| Size | Approx. 185 x 215 x 322 mm |
| Weight | Approx. 5630 g |
| Base material | Cellulose-polymer composite |
| Optimal tube voltage | 120 kVp – adaptable upon request – |
Diagnostic features
Realistic simulation of head and neck vessels up to the aortic arch, bone and soft tissues. Calcifications of the internal carotid artery at the carotid bifurcation on both sides with mild stenosis on the right side.
Packaging & Dimensions
The product ships in a protective hard case featuring interior foam padding.
- Dimensions (case): 520 x 350 x 220 mm
- Dimensions (packaged)*: 572 x 425 x 239 mm
- Total weight (ready to ship): 12.0 kg
*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.
Head / Neck Phantom CTA AVM
This phantom simulates a contrast-enhanced head in the arterial phase (CT angiography), covering the region from the vertex to the fifth cervical vertebra. The right cerebral hemisphere includes an arteriovenous malformation.
The phantom provides a detailed and realistic simulation of vascular structures, soft tissue, and bone, including fine anatomical details such as lymph nodes. Air voids are filled with a cellulose-polymer composite with an attenuation of approximately −160 HU.
It can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnostic applications, and is also well suited for training purposes.
Features
Specifications
| Size | Approx. 186 x 224 x 269 mm |
| Weight | Approx. 5120 g |
| Base material | Cellulose-polymer composite |
| Optimal tube voltage | 120 kVp – adaptable upon request – |
Diagnostic features
Realistic simulation of head and neck vessels up to the aortic arch, bone and soft tissues. Calcifications of the internal carotid artery at the carotid bifurcation on both sides with mild stenosis on the right side.
Packaging & Dimensions
The product ships in a protective hard case featuring interior foam padding.
- Dimensions (case): 520 x 350 x 220 mm
- Dimensions (packaged)*: 572 x 425 x 239 mm
- Total weight (ready to ship): 12.0 kg
*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.
Head / Neck Phantom CTA AVM / lesion
This phantom simulates a contrast-enhanced head in the arterial phase (CT angiography), covering the region from the vertex to the fifth cervical vertebra. It includes 10 low-contrast lesions in the centrum semiovale, and the right cerebral hemisphere features an arteriovenous malformation.
The phantom provides a detailed and realistic simulation of vascular structures, soft tissue, and bone. Air voids are filled with a cellulose-polymer composite with an attenuation of approximately −160 HU.
It can be used in CT (including CBCT) to evaluate and optimize imaging performance and AI-enabled diagnostic applications, and is also well suited for training purposes.
Features
Specifications
| Size | Approx. 186 x 224 x 269 mm |
| Weight | Approx. 5120 g |
| Base material | Cellulose-polymer composite |
| Optimal tube voltage | 120 kVp – adaptable upon request – |
Diagnostic features
Realistic simulation of head vessels, bone and soft tissues.
Arteriovenous malformation of the right hemisphere.
5 rod-shaped lesions on each side in the centrum semiovale at the periventricular and supraventricular level.
Lesion diameter: 10 mm
Lesion height: 10.5 mm
Lesion contrast: Approx. -60 to -20 and 20 to 60 HU at 120 kVp
Packaging & Dimensions
The product ships in a protective hard case featuring interior foam padding.
- Dimensions (case): 520 x 350 x 220 mm
- Dimensions (packaged)*: 572 x 425 x 239 mm
- Total weight (ready to ship): 12.0 kg
*Outer packaging (e.g., cardboard box or protective wrap) may vary slightly, affecting total dimensions.
Find more resources here
Brochures