IBA Dosimetry LXcan Header Image Person

LXcan

Display Quality Assurance solutions for Image Display Devices

LXcan is a Quality Assurance solution for image display devices, such as medical displays and viewing boxes, and is needed to ensure the best image quality for improved diagnosis in all x-ray modalities, such as Radiology, Fluoroscopy, Mammography, CT, and dental radiology.

For QC-tests at image display devices (grayscale) including photometric detector with achromatic optic, integrated scattered light tube and mask for screen contact measurements.

Contact us for your individual solution!
IBA Dosimetry LXcan Monitor Overview
Begin Benefit
IBA Dosimetry LXcan Dicom Curve

Unique two-in-one design

Distance and contact measurement in one device.

Innovative design

Easy targeting with a built-in camera.

Highly precise

Highly precise real-time measurement.


Full solution IBAcan Kit

Complete measuring kit for luminance measurements at image display devices (grey scale) according to: 

  • DIN 6868-157 (acceptance and constancy tests) 

  • IEC 61223-2-5 (constancy tests)

  • AAPM TG18

What's in the box?

  • Spot-Luminance-Meter LXcan

  • Mask for screen contact measurements

  • Power supply with 4 adapters (RoHs conform) - USB-cable is absolutely necessary

  • USB cable for automatic transfer of the measured data and for recharging batteries

  • Carrying case

QC Kit IBAcan

  • Display: 1.2'' TFT (65K color)
  • Alignment sensor: user definable
  • Distance sensor: ultrasonic
  • Targeting: display finder
  • F.O.V.: 1.6°
  • Measuring range: 0.05 - 10,000 cd/m2
  • f1' uncertainty: ≤3%
End Benefit

Description

  • Display: 1.2'' TFT (65K color)
  • Alignment sensor: user definable
  • Distance sensor: ultrasonic
  • Targeting: display finder
  • F.O.V.: 1.6°
  • Measuring range: 0.05 - 10,000 cd/m2
  • f1' uncertainty: ≤3%

Technical specs

  • Luminance Measurement Range: 0.05 to 10,000 cd/m2
  • Maximum Luminance Resolution: 0.03 cd/m2
  • f1`Uncertainty of V(λ) Response: ≤ 3 %
  • General Uncertainty: ≤ 10 %
  • F.O.V. Lens: ~ 1.6 °
  • Influence of Outfield Luminance f2 (U): ≤ 0.6 %
  • Stray-Light-Baffle: Integrated
  • Measurement Distance: 50 cm
  • Measurement Spot: 2 cm at 50 cm distance
  • Distance Sensor: Ultrasonic
  • Illuminance Measurement Range: 1) 0.1 to 10,000 lx (only for LX-LS)
  • Total Uncertainty: ≤ 10 %
  • Display: 1.2’’ TFT
  • Control Buttons: Three
  • Interface: USB, RS 232
  • Battery rechargeable via USB: Li-lon
  • Housing: Al; Tripod Adapter
  • Dimensions: 220 x 80 x 45 mm
  • Weight: 500 g
  • Power Consumption (use with USB): approx. 450 mA
  • Expected Operation Time (battery use): approx. 8 h