myQA Patients
Patient QA solution for gamma verification of dose distributions
Advanced Patient QA on the global QA platform, from IMRT & VMAT to SRS / SBRT plan verification, used with
Compatible with Machine/Modality/Application:
IMRT / VMAT,
Small Field Dosimetry,
TG218,
TG135,
TG148
Used for Workflow
Delivery and Plan Verification (RT),
Delivery and Plan Verification PT

Perform SRS and SBRT Patient QA
with the myQA SRS film-class detector
Use one database
to store your data
Connect staff and location
with network-based data accessibility
Protect your data integrity
with an advanced user management system
Workflow efficiency
Fast preparation of new patient data and equipment
- Enhance your clinical workflow
- Fast and seamless data preparation
- Office-based preparation
- Flexible DICOM interface
- Guided workflow navigation
- Centralized data management
Workflow-guided menu
Streamline your workflow
- Save time with fewer and optimized steps
- Save your measurements in the central database
- Analyze immediately or at your convenience
Discover myQA Patients highlights interactively

Watch the workflow
Film dosimetry
- Highest resolution without angular dependence.
- Ideal for SBRT and SRS validation & verification.
- Single- and multichannel film dosimetry supported.

Automated one-click data alignment
Auto-alignment of your measured dataset with your reference.
Speed up Patient QA workflow and provide consistent results during the measurement session:
- Automated alignment as default, manual alignment supported if necessary.
- Shifts are reported for the aligned dose maps along central axis.
- Shifts from automatic or manual alignment can be applied to all the data in the measurements folder.
Patient QA completed

One-click isocenter location
- myQA Patients automatically calculates the exact plan isocenter position based on the DICOM information.

Select isocenter plane
- Select the plane of choice manually and mark it as the isocenter plane (alternative to the automated process).

Isocenter plane definition and plane distance calculation
- The isocenter plane is automatically highlighted, including the plane position.
- Display of the distance between each dose planes according to the plan calculation grid size.
TG-218 reference dose gamma calculation
For gamma analysis, TG-218 advises to use the global normalization with reference dose selection as the better approach, compared to the maximum dose.
- myQA Patients provides reference dose gamma calculation formalism.
- For gamma analysis, select the 90% from the maximum dose, or any other value in Gy or %.
1 Watch the workflow
2 Film dosimetry
- Highest resolution without angular dependence.
- Ideal for SBRT and SRS validation & verification.
- Single- and multichannel film dosimetry supported.

3 Automated one-click data alignment
Auto-alignment of your measured dataset with your reference.
Speed up Patient QA workflow and provide consistent results during the measurement session:
- Automated alignment as default, manual alignment supported if necessary.
- Shifts are reported for the aligned dose maps along central axis.
- Shifts from automatic or manual alignment can be applied to all the data in the measurements folder.
4 Patient QA completed

5 One-click isocenter location
- myQA Patients automatically calculates the exact plan isocenter position based on the DICOM information.

6 Select isocenter plane
- Select the plane of choice manually and mark it as the isocenter plane (alternative to the automated process).

7 Isocenter plane definition and plane distance calculation
- The isocenter plane is automatically highlighted, including the plane position.
- Display of the distance between each dose planes according to the plan calculation grid size.
8 TG-218 reference dose gamma calculation
For gamma analysis, TG-218 advises to use the global normalization with reference dose selection as the better approach, compared to the maximum dose.
- myQA Patients provides reference dose gamma calculation formalism.
- For gamma analysis, select the 90% from the maximum dose, or any other value in Gy or %.

Comprehensive and efficient analysis of planned vs. measured treatments
- Wide range of algorithms for data processing
- 1D and 2D visual and mathematical analysis tools
- Relative and absolute gamma evaluation
- Rapid calculation and quick review of results in the software as well as on myQA Cockpit
What our customers say

Efficient approval management and easy reporting and archiving on the myQA central database
- Electronic approvals with the possibility to put personalized comments
- Approvals & status overview accessible everywhere on myQA Cockpit
- Template-based "one-click" fast reporting
- Export as RTF, HTML, or PDF file
- Plan approval including comments anywhere in your myQA network

Film dosimetry plug-ins in myQA Patients
Film dosimetry provides highest resolution without angular dependence and is therefore essential for SBRT and SRS validation & verification. myQA Patients supports Single- and Multichannel film dosimetry.
The Single Channel film dosimetry Film Plug-In is included in myQA Patients and provides the scanner calibration procedure (Analog to Digital Conversion to Optical Density), the film calibration (Analog to Digital Conversion to Dose) as well as a scanner artifacts correction and lateral correction.
The Multi Channel film dosimetry Film Plug-In is optionally available for myQA Patients. The Multichannel option eliminates artifacts of films and scanners, enabling highest verification accuracy for IMRT, VMAT and SBRT/SRS cases, and support of high doses.
The solution is based on the Mayer‘s Algorithm (R. Mayer et al. Med. Phys. 39 (2012) 2147).

myQA Patients with myQA Cockpit
Leverage unique time savings and keep full control by integrating your Plan Verification into your myQA global QA Platform:
- Reliable reporting of your Patient QA for documentation and audits
- Data integrity and traceability through a single central database
- Patient QA workflow efficiency including instant status management and due dates
- myQA connects staff, locations, and satellites to give you full patient data access
- myQA enables fully holistic QA - from your patients to your TPS and linac validation
- Your Patient QA on the myQA platform together with Machine QA & Beam Scanning
- Single channel film dosimetry included; Multichannel film dosimetry optional