myQA Accept

Platform-based beam scanning 

Our fully workflow-oriented, menu-guided software is designed to enhance your efficiency and significantly reduce the commissioning and QA time for your linac.

Compatible with Machine/Modality/Application:

Carbon Compatible,

C-arm linacs,

Robotic linac,

Cyclotrons,

Bore-type linacs,

Proton Therapy,

Helical linac,

Small Field Dosimetry,

Synchro-Cyclotron,

TG106,

TG135,

TG148,

TG224,

TG51

Used for Workflow

Commissioning and Annual QA PT,

Commissioning and Annual QA RT,

Monthly QA RT,

Monthly QA PT

Get in touch Get brochure

Advanced beam scanning

Efficiency with menu-guided workflows

Scan data integration in myQA

Meaningful innovation for your clinic

3D Dose Cube Import

We are the first to market with features for:

  • Validation of pre-commissioned machines
  • Pre-configured beam data validation
  • QA of your existing beam models (TPS QA)
  • Compatible with any TPS exporting in DICOM format

Innovative & independent QA to maximize patient safety

myQA Accept is the first to market commissioning and annual QA software with an integrated feature which allows you to validate your beam model against your linac.

With 3D Dose Cube Import you can import:
  • Single dose planes
  • A subset of dose planes
  • Your entire dose cube
3D Dose Cube Import is a powerful tool for validating:
  • Pre-configured beam data of pre-commissioned machines, such as
    • Elekta® Harmony
    • Varian Halcyon®/EthosTM
  • Your existing beam models (TPS QA) 

It is compatible with any treatment planning system that exports in the DICOM format. PDDs, profiles, and diagonals can be extracted for comparison.

Integrated software for your comprehensive and efficient beam scanning, commissioning, and annual QA

Automated queue generation

Automated queue generation

  • Fast & automatic data acquisition with predefined queues for all major TPS vendors
  • Save time with the smart sorting algorithm for optimized scan sequences
  • Maximize scanning efficiency with advanced queue sorting, prioritizing, and multiple queue editing
  • Intuitive setup of user-specific queues
  • Automated data export for TPS beam modeling

Data acquisition

Data acquisition

  • Adjustable scanning parameters for optimized measurement
  • 1D, 2D and 3D graphical and geometrical visualization of detector position during scanning 
  • Automatic scanning speed adaptation: Fastest scanning with optimal resolution through scanning speed adaptation

     

    Adaptive Scan Optimization (ASO)

  • Adapted scanning speed for the different profile segments
  • Optimized for accuracy in the penumbra area
  • Fast continuous scanning where fewer data points are sufficient

 

Data analysis

Data analysis

  • Accurate data analysis via standard and customizable protocols
  • 1D gamma analysis tolerances
  • Overlaying profiles for quantitative comparison
  • Library of mathematical smoothing and interpolation functions
  • Fast creation and export of data tables (PDD, TMR, OAR, etc.)

Data handling

Data handling

  • Easy data handling with advanced filtering and sorting
  • Fast creation and data export to all major TPS
  • Copy & paste to other applications, e.g., Microsoft Excel
  • Exchange data with other IBA Dosimetry applications
  • Convenient reporting

Automated queue generation

  • Fast & automatic data acquisition with predefined queues for all major TPS vendors
  • Save time with the smart sorting algorithm for optimized scan sequences
  • Maximize scanning efficiency with advanced queue sorting, prioritizing, and multiple queue editing
  • Intuitive setup of user-specific queues
  • Automated data export for TPS beam modeling

Data acquisition

  • Adjustable scanning parameters for optimized measurement
  • 1D, 2D and 3D graphical and geometrical visualization of detector position during scanning 
  • Automatic scanning speed adaptation: Fastest scanning with optimal resolution through scanning speed adaptation

     

    Adaptive Scan Optimization (ASO)

  • Adapted scanning speed for the different profile segments
  • Optimized for accuracy in the penumbra area
  • Fast continuous scanning where fewer data points are sufficient

 

Data analysis

  • Accurate data analysis via standard and customizable protocols
  • 1D gamma analysis tolerances
  • Overlaying profiles for quantitative comparison
  • Library of mathematical smoothing and interpolation functions
  • Fast creation and export of data tables (PDD, TMR, OAR, etc.)

Data handling

  • Easy data handling with advanced filtering and sorting
  • Fast creation and data export to all major TPS
  • Copy & paste to other applications, e.g., Microsoft Excel
  • Exchange data with other IBA Dosimetry applications
  • Convenient reporting
Efficiency with menu-guided workflows
  • Fastest scanning with optimal resolution through scanning speed adaptation
  • Automatic queue generation
Fully workflow oriented, menu guided software designed to increase your efficiency and to reduce the commissioning and QA time of your linac
  • All your QA data connected via one central platform, providing you with full control and accessibility
  • Connect your scan data and use them as your individual “gold standard” reference (e.g., for Machine QA)
Scan data integration in myQA
  • Use your commissioning scans as a reference with your other myQA applications (e.g., for Machine QA)

Beam scanning and annual QA. Automated.

Beam scanning. Guided.

Beam scanning. Guided.

SMARTSCANTM guides the user screen by screen through the scanning workflow, from preparation to execution. To minimize manual changes, SMARTSCANTM groups all tasks and suggests settings for the linac. As soon as the Stealth Chamber detects the beam, SMARTSCANTM automatically performs the next group of measurements. Similarly, the user is guided whenever a change of detector or other setup task is required.

Beam scanning. Automated.

Beam scanning. Automated.

SMARTSCANTM automates most of the repetitive tasks while executing the beam scan queue. Every beam profile and depth dose curve [FF/FFF] measurement is instantly checked for flatness, beam symmetry, and signal noise. If the set limit values are exceeded, SMARTSCANTM informs the user immediately. After three consecutive poor measurements, SMARTSCANTM pauses and suggests a setup check; otherwise, further measurements would be wasted. In addition, SMARTSCANTM repeatedly checks background noise and performs electrometer normalizations for every field.

Annual QA made easy, fast and accurate.

Annual QA made easy, fast and accurate.

SMARTSCANTM overcomes the typical challenges and constraints of using standard water phantoms for annual QA.

Instead, annual QA is converted into an easy and fast process using SMARTSCANTM.

Easy & fast annual QA with SMARTSCANTM

  • Standardized and automated annual QA workflow.
  • Easy comparison from year to year / between machines and clinics.
  • Fast system setup in 12 minutes.
  • Automated parameter settings for each scan.
  • Scan automation and user guidance minimize human interaction and save time.
  • No need for manual data analysis at the end of your scanning.

Accurate annual QA with SMARTSCANTM

  • Superior quality of your annual QA data - Automated.
  • Sub-millimeter setup accuracy through user validation and automated software checks.
  • Automated scan validation checks ensure you measure the correct scans.
  • Instant quality checks of each scan result in highest data quality.
  • Automated data comparison vs. your protocol / reference data.
  • Depth dose scans enable annual QA accuracy (vs. 2D detector QA).

Due to its ease of use and accuracy, SMARTSCANTM is the ideal solution and frequently used for annual QA!

Beam scanning. Guided.

SMARTSCANTM guides the user screen by screen through the scanning workflow, from preparation to execution. To minimize manual changes, SMARTSCANTM groups all tasks and suggests settings for the linac. As soon as the Stealth Chamber detects the beam, SMARTSCANTM automatically performs the next group of measurements. Similarly, the user is guided whenever a change of detector or other setup task is required.

Beam scanning. Automated.

SMARTSCANTM automates most of the repetitive tasks while executing the beam scan queue. Every beam profile and depth dose curve [FF/FFF] measurement is instantly checked for flatness, beam symmetry, and signal noise. If the set limit values are exceeded, SMARTSCANTM informs the user immediately. After three consecutive poor measurements, SMARTSCANTM pauses and suggests a setup check; otherwise, further measurements would be wasted. In addition, SMARTSCANTM repeatedly checks background noise and performs electrometer normalizations for every field.

Annual QA made easy, fast and accurate.

SMARTSCANTM overcomes the typical challenges and constraints of using standard water phantoms for annual QA.

Instead, annual QA is converted into an easy and fast process using SMARTSCANTM.

Easy & fast annual QA with SMARTSCANTM

  • Standardized and automated annual QA workflow.
  • Easy comparison from year to year / between machines and clinics.
  • Fast system setup in 12 minutes.
  • Automated parameter settings for each scan.
  • Scan automation and user guidance minimize human interaction and save time.
  • No need for manual data analysis at the end of your scanning.

Accurate annual QA with SMARTSCANTM

  • Superior quality of your annual QA data - Automated.
  • Sub-millimeter setup accuracy through user validation and automated software checks.
  • Automated scan validation checks ensure you measure the correct scans.
  • Instant quality checks of each scan result in highest data quality.
  • Automated data comparison vs. your protocol / reference data.
  • Depth dose scans enable annual QA accuracy (vs. 2D detector QA).

Due to its ease of use and accuracy, SMARTSCANTM is the ideal solution and frequently used for annual QA!

What our customers say

  • myQA Accept

    "IBA has mastered dosimetry software for commissioning and annual QA with myQA Accept. One of the easiest to use and most intuitive scanning and data analysis solutions out there. The first time I used it, after setting up the water tank and probes, I dove right in without having to read the instructions. Within minutes, I was rewarded with smoothed profiles and percentage ionization curves. With a simple click, my ionization curve was converted to a depth dose curve. Easy sidebar navigation made it easy to change the reported analysis of my curve. TG-51 or IAEA values? Four different ways to estimate electron energies. Countless other analysis options simply require a click of a check box."

    "myQA Accept is a great tool that is intuitive, easy to use and stable, saving time (and a little bit of my weekend) when annuals come around."

     

    Robert Krauss, Medical Physicist, St. Francis Hospital, Memphis TN, USA

    Find more information here

    Brochures

    INTEGRATED BEAM SCANNING & ANNUAL QA
    Brochures (3 MB)
    Download now

    Contact us for more information

    Related Products